Find Bi-directional Module 3Km, 1.25G Bi-directional Module, 3Km Bi-directional Module on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Home > Products > Optical Transeciver > 1G BiDi Transeciver > 1.25G Bi-directional Module Fiber Optical 3Km

1.25G Bi-directional Module Fiber Optical 3Km

Basic Info

Model No.: iB-3506-03BD

Product Description

Product Description




iB-3506-03BD

SFP BIDI 1.25G 1310/1550nm(1550/1310nm)nm 3KM Transceiver

Features

· Up to 1.25Gb/s data links

· FP laser transmitter for iSF-BL3512-20D

· DFB laser transmitter for iSF-BL5312-20D

· PIN photo-detector

· Up to 3km on 9/125µm SMF

· Hot-pluggable SFP footprint

· BIDI LC/UPC type pluggable optical interface

· Low power dissipation

· Metal enclosure, for lower EMI

· RoHS compliant and lead-free

· Single +3.3V power supply

· Support Digital Diagnostic Monitoring interface

· Compliant with SFF-8472

· Case operating temperature

Commercial: 0°C to +70°C

Extended: -10°C to +80°C

Industrial: -40°C to +85°C


1 25g Bidi Sfp Tx1310rx1550nm 3km Fiber Transeciver 5 540x1 25g Bidi Sfp Tx1310rx1550nm 3km Fiber Transeciver 4 540x


Applications

· Switch to Switch Interface

· Gigabit Ethernet

· Switched Backplane Applications

· Router/Server Interface

· Other Optical Links

Description

Xmethod Network Small Form Factor Pluggable (SFP) transceivers are compatible with the Small Form Factor Pluggable Multi-Sourcing Agreement (MSA), The transceiver consists of five sections: the LD driver, the limiting amplifier, the digital diagnostic monitor, the 1310nm FP laser (the 1550nm DFB laser) and the PIN photo-detector. The module data link up to 3KM in 9/125um single mode fiber.

The optical output can be disabled by a TTL logic high-level input of Tx Disable, and the system also can disable the module via I2C. Tx Fault is provided to indicate that degradation of the laser. Loss of signal (LOS) output is provided to indicate the loss of an input optical signal of receiver or the link status with partner. The system can also get the LOS (or Link)/Disable/Fault information via I2C register access.

Absolute Maximum Ratings

Parameter

Symbol

Min

Typ

Max

Unit

Note

Storage Temperature

Ts

-40

85

ºC

Storage Ambient Humidity

HA

5

95

%

Power Supply Voltage

VCC

-0.5

4

V

Signal Input Voltage

-0.3

Vcc+0.3

V

Receiver Damage Threshold

5

dBm


Recommended Operating Conditions

Parameter

Symbol

Min

Typ

Max

Unit

Note

Case Operating Temperature

Tcase

0

70

ºC

commercial

-10

80

extended

-40

85

industrial

Ambient Humidity

HA

5

70

%

Non-condensing

Power Supply Voltage

VCC

3.13

3.3

3.47

V

Power Supply Current

ICC

280

mA

Power Supply Noise Rejection

100

mVp-p

100Hz to 1MHz

Data Rate

1.25/1.25

Gbps

TX Rate/RX Rate

Transmission Distance

3

KM

Coupled Fiber

Single mode fiber

9/125um SMF

Electrical Characteristics

Parameter

Symbol

Min

Typ

Max

Unit

Note

Transmitter

Total Supply Current

ICC

A

mA

Note (1)

Transmitter Disable Input-High

VDISH

2

Vcc+0.3

V

Transmitter Disable Input-Low

VDISL

0

0.8

V

Transmitter Fault Input-High

VDISL

2

Vcc+0.3

V

Transmitter Fault Input-Low

VTxFH

0

0.8

V

Receiver

Total Supply Current

ICC

B

mA

Note (1)

LOSS Output Voltage-High

VLOSH

2

Vcc+0.3

V

LVTTL

LOSS Output Voltage-Low

VLOSL

0

0.8

V

Notes:

A (TX) + B (RX) = 280mA (Not include termination circuit)

Optical Characteristics

Parameter

Symbol

Min

Typ

Max

Unit

Note

Transmitter

Average Output Power

POUT

-9

-3

dBm

Extinction Ratio

ER

9

dB

Center Wavelength

λC

1290

1310

1330

nm

1530

1550

1570

Spectrum Width (RMS)

σ

3.5

nm

FP Laser

(TX:1310nm)

Side Mode Suppression Ratio

SMSR

30

dB

DFB Laser

(TX:1550nm)

Spectrum Bandwidth(-20dB)

σ

1

nm

Transmitter OFF Output Power

POff

-45

dBm

Differential Line Input Impedance

RIN

90

100

110

Ohm

Jitter P-P

tJ

0.1

UI

Note (1)

Output Eye Mask

Compliant with IEEE802.3 z (class 1 laser safety)

Note (2)

Receiver

Input Optical Wavelength

λIN

1530

1550

1570

nm

1290

1310

1330

Receiver Sensitivity

PIN

-22

dBm

Note (3)

Input Saturation Power (Overload)

PSAT

-3

dBm

Los Of Signal Assert

PA

-35

dBm

Los Of Signal De-assert

PD

-21

dBm

Note (4)

LOS Hysteresis

PA-PD

0.5

2

6

dB

Notes:

· Measure at 2^7-1 NRZ PRBS pattern

· Transmitter eye mask definition

· Measured with Light source 1550nm(1310nm), ER=9dB; BER =<10^-12 PRBS=2^7-1 NRZ.

· When LOS de-asserted, the RX data+/- output is signal output.

Bi Directional Module 40km

Pin Descriptions

Pin

Symbol

Name/Description

Note

1

VEET

Transmitter Ground (Common with Receiver Ground)

1

2

TFAULT

Transmitter Fault.

3

TDIS

Transmitter Disable. Laser output disabled on high or open.

2

4

MOD_DEF(2)

Module Definition 2. Data line for Serial ID.

3

5

MOD_DEF(1)

Module Definition 1. Clock line for Serial ID.

3

6

MOD_DEF(0)

Module Definition 0. Grounded within the module.

3

7

Rate Select

No connection required

4

8

LOS

Loss of Signal indication. Logic 0 indicates normal operation.

5

9

VEER

Receiver Ground (Common with Transmitter Ground)

1

10

VEER

Receiver Ground (Common with Transmitter Ground)

1

11

VEER

Receiver Ground (Common with Transmitter Ground)

1

12

RD-

Receiver Inverted DATA out. AC Coupled

13

RD+

Receiver Non-inverted DATA out. AC Coupled

14

VEER

Receiver Ground (Common with Transmitter Ground)

1

15

VCCR

Receiver Power Supply

16

VCCT

Transmitter Power Supply

17

VEET

Transmitter Ground (Common with Receiver Ground)

1

18

TD+

Transmitter Non-Inverted DATA in. AC Coupled.

19

TD-

Transmitter Inverted DATA in. AC Coupled.

20

VEET

Transmitter Ground (Common with Receiver Ground)

1

Notes:

· Circuit ground is internally isolated from chassis ground.

· Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.

· Should be pulled up with 4.7k - 10kohms on host board to a voltage between 2.0V and 3.6V.MOD_DEF(0) pulls line low to indicate module is plugged in.

· This is an optional input used to control the receiver bandwidth for compatibility with multiple data rates (most likely Fiber Channel 1x and 2x Rates). If implemented, the input will be internally pulled down with > 30kΩ resistor. The input states are:

Low (0 – 0.8V): Reduced Bandwidth

(>0.8V, < 2.0V): Undefined

High (2.0 – 3.465V): Full Bandwidth

Open: Reduced Bandwidth

· LOS is open collector output. Should be pulled up with 4.7k - 10kohms on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.

Bi Directional Module 40km

Pin out of Connector Block on Host Board

Xmethod NetworK iB-3506-03BD transceivers support the 2-wire serial communication protocol as defined in the SFP MSA. It is very closely related to the E2PROM defined in the GBIC standard, with the same electrical specifications.

The standard SFP serial ID provides access to identification information that describes the transceiver’s capabilities, standard interfaces, manufacturer, and other information.

Additionally, Xmethod Network SFP transceivers provide an unique enhanced digital diagnostic monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage. It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range.

The SFP MSA defines a 256-byte memory map in E2PROM that is accessible over a 2-wire serial interface at the 8 bit address 1010000X (A0h). The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally defined serial ID memory map remains unchanged. The interface is identical to, and is thus fully backward compatible with both the GBIC Specification and the SFP Multi Source Agreement.

The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the SFP transceiver into those segments of the E2PROM that are not write-protected. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially.

Digital diagnostics for the iB-3506-03BD are Internally calibrated by default.

Outline Specifications

1 25g Bi Directional Module 3km

Regulatory Compliance

Feature

Reference

Performance

Electrostatic dischargeESD

IEC/EN 61000-4-2

Compatible with standards

Electromagnetic Interference (EMI)

FCC Part 15 Class B EN 55022 Class B (CISPR 22A)

Compatible with standards

Laser Eye Safety

FDA 21CFR 1040.10, 1040.11 IEC/EN 60825-12

Class 1 laser product

Component Recognition

IEC/EN 60950 UL

Compatible with standards

ROHS

2002/95/EC

Compatible with standards

EMC

EN61000-3

Compatible with standards

Ordering information

Part Number

Product Description

iB-3506-03BD

1310/1550nm(1550/1310nm) , FP, 1.25Gb/s, 3KM, DDM

Revision History

Revision

Notes

Authors

Checked

Approval

Date

Rev A0

New release

Granger.Leung

2014.11.11




Contact us if you need more details on Bi-directional Module 3Km. We are ready to answer your questions on packaging, logistics, certification or any other aspects about 1.25G Bi-directional Module、3Km Bi-directional Module. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Optical Transeciver > 1G BiDi Transeciver